LCFP-A10 is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. It is designed as per “Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)” ASTM D93.

Ambient temperature ≤ 35 °C
Relative humidity ≤ 85 %
Temperature range 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device 0.8 mm
Standard oil cup-Inner diameter 50.7 ~ 50.8 mm
Standard oil cup- Depth 55.7 ~ 56.0 mm
Standard oil cup- Depth of Marked line on the oil cup 33.9 ~ 34.3 mm
Standard oil cup-Oil sample cubage About 70 ml
Stirring speed 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B
Stirring blade 8 × 40 mm
Sample temperature rising rate 1 ~ 12 °C per minute
Heating power 0 ~ 600 W
Dimension 420 × 350 × 350 mm
Total Power Consumption 600 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Ignition source : Coal gas
  • Rod type Mercury Thermometer
  • Variable Temperature Range
  • 45TYZ Stirring Motor
It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 °C

Closed Cup Flash Point Tester

Automatic PMCC Flash Point Tester LCFP-A13

Automatic PMCC Flash Point Tester LCFP-A13

  • Ambient temperature
  • 10 °C ~ 40 ℃
  • Relative humidity
  • ≤ 80 %
  • Ignition Mode
  • electron igniter / gas flame
Automatic PMCC Flash Point Tester LCFP-A11

Automatic PMCC Flash Point Tester LCFP-A11

  • Ambient temperature
  • 10 °C ~ 40 °C
  • Relative humidity
  • ≤ 80 %
  • Measurement Range
  • Ambient Temperature ~ 250 °C

Automatic Bomb Calorimeter

Automatic Bomb Calorimeter LABC-A11

Automatic Bomb Calorimeter LABC-A11

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-A10

Automatic Bomb Calorimeter LABC-A10

  • Calorimeter type
  • Isoperibol
  • Temperature range
  • 5 to 40°C
  • Measurement range
  • 5 to 40 MJ/ kg
Automatic Bomb Calorimeter LABC-B11

Automatic Bomb Calorimeter LABC-B11

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Semi-automatic
  • Bomb volume
  • 282 ml
Automatic Bomb Calorimeter LABC-B10

Automatic Bomb Calorimeter LABC-B10

  • Calorimeter type
  • Isoperibol
  • Oxygen filling
  • Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
  • Bomb volume
  • 250 ml

Octane Number & Cetane Number Tester

Octane Number and Cetane Number Tester LOCT-A10

Octane Number and Cetane Number Tester LOCT-A10

  •  Measuring Range For Aviation Gasoline
  • 86.0 to 105.0/MON
  •  Measuring Range For Gasoline For Motor Vehicles
  • National standard: 65.0 to 110.0/RON National-V standard: 70 to 115.0/RON Blended gasoline: 75.0 to 120.0/RON Light gasoline: 50.0 to 85.0 /MON Isomerized gasoline: 85.0 to 120.0/RON Arene gasoline: 90.0 to 120.0/RON
  •  Measuring Range For Ethanol
  • E93: 92.0 to 95.0/RON E97: 95.0 to 99.0/RON Judgement: 60.0 to 120.0/RON
Portable Octane Number and Cetane Meter LOCT-A20

Portable Octane Number and Cetane Meter LOCT-A20

  • Measurement item
  • motor gasoline and diesel
  • measurement unit of octane is ON
  • 40 to 120
  • Permissible error of octane
  • ± 0.5 max

Acid and Alkali Tester

Base Number Tester LAAT-A13

Base Number Tester LAAT-A13

  • Volumetric analysis
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
  • Automatic acid titration
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
  • Automatic potential control
  • Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Acid Number Tester LAAT-A12

Acid Number Tester LAAT-A12

  • Measurement range
  • ≥0.05 mg KOH/g
  • Potential measurement range
  • 0 to 1800.0 mV
  • Burette volume
  • 10 mL
Water Soluble Acid and Alkali Tester LAAT-A10

Water Soluble Acid and Alkali Tester LAAT-A10

  • Graduated flask
  • 100 ml,50 ml
  • Conical flask
  • 100ml
  • Separatory funnel
  • 250ml
Acid Number and Acidity Tester LAAT-A11

Acid Number and Acidity Tester LAAT-A11

  • Ambient temperature
  • ≤ 35 °C
  • Relative humidity
  • ≤ 85 %
  • Precision of titration tube
  • Scale division is 0.02 ml

Aniline Test Equipment

Aniline Point Tester LAPT-A10

Aniline Point Tester LAPT-A10

  • Measurement range
  • Room temperature ~ 150°C
  • Stirring speed
  • 0 ~ 1200 r / min
  • Heating power
  • 25 W
Aniline Point Tester LAPT-A11

Aniline Point Tester LAPT-A11

  • Temperature controlling accuracy
  • ≤ 0.5 ℃
  • Temperature controlling range
  • Room temperature ~ 200 ℃
  • Power supply for illumination
  • 5 V