Bekk Smoothness tester TP-L20 with microprocessor controlled system is used for determination of smoothness of the paper & cardboard by ‘Bekk Method’. Equipped with high-precision sensor and imported oil-free vacuum pump for smooth operations. The test results generated with Bekk smoothness tester, has shown correlation with print smoothness evaluation using offset ink.

Measuring scope ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy ±0.1 s within 300 s
Vacuum system volume (ml) Bigger volume: 380 ± 1<br/> Smaller volume: 38 ± 1
Contact pressure 100 ± 2 kPa
Vacuum scope I) 50.66 to 48.00<br/> II) 50.66 to 48.00<br/> III) 50.66 to 29.33<br/> Automatic: No limit
Air volume (50.66 kPa down to 48.00 kPa) Big vacuum volume: 10.00 ± 0.20 ml<br/> Small vacuum volume: 1.00 ± 0.05 ml
Dimension 325×390×430 mm
Net weight 30 kg
Power supply AC220 V ± 10 % , 50 Hz
  • Fast measurement mode
  • Adopted with vacuum sealed plastic & advanced sealing technology
  • 7 inch colored touch screen
  • CAM & spring structure design with 100 N pressure
  • Data communication via PC software
  • USB cable connection
Smoothness tester is used in testing smoothness of coated label papers, sheets, smooth textures papers, printing papers photographs papers etc. in paper, printing packaging industry.

Paper Testing Instruments

Automatic horizontal tensile tester TP-B11

Automatic horizontal tensile tester TP-B11

  • Sample (size) length
  • 90 to 200 mm
  • Sample width
  • 15 mm, 25 mm, 50mm
  • Measuring range
  • 0 to 30, 0 to 100 N,0 to 300 N
COBB sample cutter TP-C30

COBB sample cutter TP-C30

  • Sample diameter
  • 125 mm
  • Sample error
  • ± 0.2 mm
  • Sample Thickness
  • 0.1 to 1.0 mm
Mullen burst tester TP-K10

Mullen burst tester TP-K10

  • Measurement range
  • 0 to 5600 kPa
  • Accuracy
  • ± 0.5 % F.S.
  • Compression speed
  • 170 ± 15 ml/min
Softness tester TP-H10

Softness tester TP-H10

  • Measuring range
  • 10 to 1000 mN
  • Division value
  • 1 mN
  • Accuracy
  • ± 1%

Plastic Testing Instruments

Vicat softening temperature & HDT machine TVHT-A10

Vicat softening temperature & HDT machine TVHT-A10

  • Operating temperature
  • Ambient temperature to 300°C
  • Heating rate
  • 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
  • Maximum temp. error with heating speed
  • ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Falling Weight Impact Tester TFWT-A10

Falling Weight Impact Tester TFWT-A10

  • Temperature range
  • 10 to 35°C
  • Maximum falling height
  • 2000 mm
  • Resolution of displacement
  • 1 mm
Lasting adhesive tester TLAT-A10

Lasting adhesive tester TLAT-A10

  • Standard roller
  • 2000 ± 50 g
  • Testing stations
  • 3
  • Dimension (L*W*H) tester
  • 320×210×550 mm (3 stations)
Heat sealer THS-A10

Heat sealer THS-A10

  • Seal temperature
  • Room temperature -250°C
  • Control accuracy
  • ± 0.2°C
  • Dwell time
  • 0.1 S to 999.9 S

Rubber Testing Instruments

Three roll mill machine TRMM-A10

Three roll mill machine TRMM-A10

  • Mixed capacity
  • 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
  • Temperature range
  • RT to 300°C
  • Temperature control system
  • PID control
No rotor rheometer TNRR-A10

No rotor rheometer TNRR-A10

  • Temperature tester
  • Room temperature to 200°C
  • Temperature display resolution
  • 0.1°C
  • Temperature control accuracy
  • ≤ ± 0.3°C
Rubber-weiss plasticity testing machine TRWM-A10

Rubber-weiss plasticity testing machine TRWM-A10

  • Temperature range
  • RT 50° to 300°
  • Temperature accuracy
  • ± 1°
  • Measuring range
  • 0.01 to 25 mm
Mooney viscometer TMV-A10

Mooney viscometer TMV-A10

  • Control temperature range
  • Normal temperature to 200°C
  • Temperature display resolution
  • 0.01°C
  • Temperature control accuracy
  • ± 0.3°

NDT Testing Instruments

Rockwell hardness meter TRHM-A11

Rockwell hardness meter TRHM-A11

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Total test force dwell time
  • 1 to 30 S
Portable Vibration Calibrator LPVC-A10

Portable Vibration Calibrator LPVC-A10

  • Frequency (continually adjustable)
  • 10 Hz to1280 Hz + 0.01 %
  • Amplitude acceleration ( at 30m/s2 pk )
  • 40 Hz to 320 Hz + 0.3 dB + 1 digit
  • Amplitude velocity ( at 25mm / sec pk )
  • 40 Hz to 320 Hz + 0.5dB +1 digit
Digital low load Vickers Hardness tester TDVH-A10

Digital low load Vickers Hardness tester TDVH-A10

  • Test force
  • 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
  • Hardness value symbol
  • HV1, HV5, HV10, HV20, HV30, HV250
  • Error range in display
  • ± 3.0 %, ± 2.0 %
Rockwell hardness meter (motorized type) TRHM-B10

Rockwell hardness meter (motorized type) TRHM-B10

  • Preliminary test force
  • 98 N
  • Total test force
  • 588, 980, 1471 N
  • Brinell hardness test
  • 306, 613, 1839 N

Other Testing Instruments

Benchtop gloss meter TBGM-A10

Benchtop gloss meter TBGM-A10

  • Test angle
  • 60°
  • Gloss aperture
  • 2 × 3 mm
  • Measurement range
  • 0 to 1000 GU